THHN/THWN-2 Cable

Cablcon THHN/THWN-2 copper conductors are Thermoplastic High Heat-resistant 600V cables primarily used in conduit and cable trays for commercial or industrial applications. THWN has the additional benefit of water resistance due to its Nylon coating. THHN/THWN-2 copper conductors are designed to be installed without the application of a pulling lubricant. These conductors have multiple ratings depending upon the product application.

Its robust construction and compliance with industry standards provide reliable performance and durability for demanding environments. Contact Cablcon today to meet with our team of engineers ready to support you with custom solution designs.

Image of a black THHN cable


Applications

  • Designed for harsh environments
  • Ideal for residential wiring, commercial buildings, underground conduits and cable trays
  • Suitable for environments requiring:
    • High voltage power (600V rated)
    • UV resistance (8AWG and larger)
    • Indoor and outdoor installations
    • CT rated conductor (1/0 AWG and larger)

Construction

  • Conductors:
    • Concentric-Lay-Stranded Copper
    • Wire Combination Unilay-Stranded Copper
  • Insulation: Heat, moisture, Gasoline and Oil Resistant II PVC
  • Sheath: Nylon Jacket

Features

  • Stranding Types:
    • Stranded Combination-Ulinay: sizes 8 AWG – 3/0 AWG
    • Stranded Compressed: sized 4/0 AWG & larger
    • Class C stranding: sizes 8 AWG – 2 AWG
    • Class B stranding: sizes 1 kcmil – 1000 kcmil
  • Voltage: 600V rating
  • Temperature Ratings:
    • THHN: Dry locations up to 90°C
    • THWN-2: Wet/dry locations up to 90°C or 75°C when exposed to oil
  • Flame Performance: VW-1 / FT-1 (all sizes)

Standards & Certifications

  • RoHS Compliant
  • ASTM B8 and ASTM B787 – 19 Conductors
  • UL® 83, UL® 758, UL® 1063, UL® 1685 and c(UL) Listed
  • CSA C22.2 No. 75
  • ICEA S-95-658 (NEMA WC70) – Power cables ≤ 2000 volts
  • Federal Spec A-A-59544
  • NMX-J-010-ANCE
  • NOM-063-SCFI
  • Eligible for LEED v4.1 MRc6 credit (Lead content < 300 ppm)


Weights & Measurements

This table provides detailed physical specifications for Cablcon’s THHN/THWN-2 cables, including conductor size, strand count, insulation and jacket thickness, overall cable diameter, and weight. These values help ensure proper fit and installation planning for commercial, industrial, and residential electrical projects.

Part Number
Cond. Size (AWG/Kcmil) Cond. Number Strand Count Diameter Over Conductor (in) Insul. Thickness (mil) Jacket Thickness (mil) Approx. OD (in) Copper Weight (lb/1000ft) Approx. Weight (lb/1000ft)
THHN08B19-X 8 1 19 0.143 31 6 0.217 50 63
THHN06B19-X 6 1 19 0.179 31 6 0.253 81 95
THHN04B19-X 4 1 19 0.226 41 7 0.322 128 153
THHN03B19-X 3 1 19 0.254 41 7 0.35 162 189
THHN02B19-X 2 1 19 0.286 41 7 0.382 204 235
THHN01B19-X 1 1 19 0.322 52 8 0.439 258 301
THHN1/0B19-X 1/0 1 19 0.361 52 8 0.48 326 374
THHN2/0B19-X 2/0 1 19 0.405 52 8 0.524 410 464
THHN3/0B19-X 3/0 1 19 0.456 52 8 0.574 518 578
THHN4/0B19-X 4/0 1 19 0.512 52 8 0.627 653 719
THHN250B37-X 250 1 37 0.558 62 9 0.684 771 844
THHN300B37-X 300 1 37 0.61 62 9 0.753 926 1016
THHN350B37-X 350 1 37 0.661 62 9 0.803 1080 1180
THHN400B37-X 400 1 37 0.705 62 9 0.848 1235 1341
THHN500B37-X 500 1 37 0.789 62 9 0.931 1543 1662
THHN600B61-X 600 1 61 0.865 70 10 1.03 1852 1992
THHN750B61-X 750 1 61 0.968 70 10 1.132 2315 2470
THHN1000B61-X 1000 1 61 1.117 70 10 1.281 3087 3264

*All dimensions are nominal and subject to normal manufacturing tolerances

*TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Electrical & Engineering Data

This table outlines key electrical performance characteristics of THHN/THWN-2 cables. It includes values for bending radius, maximum pull tension, DC and AC resistance, inductive reactance, and allowable ampacity ratings at 75°C and 90°C. These specs are essential for engineers calculating electrical load capacity and installation conditions.

Part Number
Cond. Size (AWG/Kcmil) Cond. Number Min Bending Radius (in) Max Pull Tension (lb) DC Resistance at 25°C (Ω/1000ft) AC Resistance at 75°C (Ω/1000ft) Inductive Reactance at 60Hz (Ω/1000ft) Allowable Ampacity at 75°C (Amp) Allowable Ampacity at 90°C (Amp)
THHN08B19-X 8 1 0.9 132 0.653 0.786 0.052 50 55
THHN06B19-X 6 1 1 209 0.411 0.495 0.051 65 75
THHN04B19-X 4 1 1.3 333 0.258 0.31 0.048 85 95
THHN03B19-X 3 1 1.4 420 0.205 0.246 0.047 100 115
THHN02B19-X 2 1 1.5 530 0.162 0.195 0.045 115 130
THHN01B19-X 1 1 1.8 669 0.128 0.154 0.046 130 145
THHN1/0B19-X 1/0 1 1.9 844 0.102 0.122 0.044 150 170
THHN2/0B19-X 2/0 1 2.1 1064 0.081 0.097 0.043 175 195
THHN3/0B19-X 3/0 1 2.3 1342 0.064 0.078 0.042 200 225
THHN4/0B19-X 4/0 1 2.5 1692 0.051 0.062 0.041 230 260
THHN250B37-X 250 1 2.7 2000 0.043 0.053 0.041 255 290
THHN300B37-X 300 1 3 2400 0.036 0.045 0.041 285 320
THHN350B37-X 350 1 3.2 2800 0.031 0.039 0.04 310 350
THHN400B37-X 400 1 3.4 3200 0.027 0.035 0.04 335 380
THHN500B37-X 500 1 3.7 4000 0.022 0.029 0.039 380 430
THHN600B61-X 600 1 5.2 4800 0.018 0.025 0.039 420 475
THHN750B61-X 750 1 5.7 6000 0.014 0.022 0.038 475 535
THHN1000B61-X 1000 1 6.4 8000 0.011 0.018 0.037 545 615

* Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.

* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center

Stock Code by Color and Size

This table displays stock codes for Cablcon’s THHN/THWN-2 cables based on wire size and insulation color. Use this reference to identify the correct part number for your required strand size and color combination, streamlining ordering and inventory management.

Size (Strand) 0-Black 1-Red 3-Blue 9-White 6-Brown 5-Orange 4-Yellow 8-Gray 2-Green 7-Purple
8 (19) 204883 204909 204917 204891 238477 238493 238485 238501 204925 256586
6 (19) 204933 204958 204966 204941 260695 260679 260687 254649 204974 485607
4 (19) 204990 204982 205633 205005 411702 411710 411694 611778 251728 552486
3 (19) 243469 243485 372763 243477 551078 551079 551080 551081 601971 552533
2 (19) 205021 205013 315812 205039 610169 610171 420653 610172 295832 552534
1 (19) 205047 344598 481945 344580 550890 550888 550887 550891 400192 552488
1/0 (19) 205054 558773 558774 558771 558778 558779 558777 558781 556315 551539
2/0 (19) 205062 556113 556114 556111 556119 556117 556116 558784 556115 552535
3/0 (19) 205070 556121 556122 556120 556127 556125 556124 556698 556123 551541
4/0 (19) 205088 556129 556130 556128 556135 556133 556132 556697 556131 551540
250 (37) 205096 556137 556138 556136 556143 556141 556140 556552 556139 551025
300 (37) 205104 556145 556146 556144 556150 556149 556148 556551 556147 551026
350 (37) 205112 556152 556153 556151 556157 556156 556155 556707 556154 551027
400 (37) 205120 556160 556161 556158 556165 556164 556163 556550 556162 551029
500 (37) 205138 556168 556169 556166 556173 556172 556171 556549 556170 551599
600 (61) 321471 556176 556177 556174 556181 556180 556179 558859 556178 552485
750 (61) 320994 564946 564944 564945 550909 550908 550907 550910 551700 552536
1000 (61) 289710


552644
552645
552647
564234

Versatile Copper Cable for Industrial and Commercial Use

Cablcon’s THHN, THWN-2, MTW, and DLO cables are built with copper conductors and tough PVC insulation, making them ideal for demanding environments up to 600V. Certified to UL and CSA standards and supported by value-added services like custom cutting and labeling.

54080