Cablcon.com

THHN/THWN-2 Cable

Cablcon THHN/THWN-2 copper conductors are Thermoplastic High Heat-resistant 600V cables primarily used in conduit and cable trays for commercial or industrial applications. THWN has the additional benefit of water resistance due to its Nylon coating. THHN/THWN-2 copper conductors are designed to be installed without the application of a pulling lubricant. These conductors have multiple ratings depending upon the product application.

Its robust construction and compliance with industry standards provide reliable performance and durability for demanding environments. Contact Cablcon today to meet with our team of engineers ready to support you with custom solution designs.

Image of a black THHN cable


Applications

  • Designed for harsh environments
  • Ideal for residential wiring, commercial buildings, underground conduits and cable trays
  • Suitable for environments requiring:
    • High voltage power (600V rated)
    • UV resistance (8AWG and larger)
    • Indoor and outdoor installations
    • CT rated conductor (1/0 AWG and larger)

Construction

  • Conductors:
    • Concentric-Lay-Stranded Copper
    • Wire Combination Unilay-Stranded Copper
  • Insulation: Heat, moisture, Gasoline and Oil Resistant II PVC
  • Sheath: Nylon Jacket

Features

  • Stranding Types:
    • Stranded Combination-Ulinay: sizes 8 AWG – 3/0 AWG
    • Stranded Compressed: sized 4/0 AWG & larger
    • Class C stranding: sizes 8 AWG – 2 AWG
    • Class B stranding: sizes 1 kcmil – 1000 kcmil
  • Voltage: 600V rating
  • Temperature Ratings:
    • THHN: Dry locations up to 90°C
    • THWN-2: Wet/dry locations up to 90°C or 75°C when exposed to oil
  • Flame Performance: VW-1 / FT-1 (all sizes)

Standards & Certifications

  • RoHS Compliant
  • ASTM B8 and ASTM B787 – 19 Conductors
  • UL® 83, UL® 758, UL® 1063, UL® 1685 and c(UL) Listed
  • CSA C22.2 No. 75
  • ICEA S-95-658 (NEMA WC70) – Power cables ≤ 2000 volts
  • Federal Spec A-A-59544
  • NMX-J-010-ANCE
  • NOM-063-SCFI
  • Eligible for LEED v4.1 MRc6 credit (Lead content < 300 ppm)


Weights & Measurements

This table provides detailed physical specifications for Cablcon’s THHN/THWN-2 cables, including conductor size, strand count, insulation and jacket thickness, overall cable diameter, and weight. These values help ensure proper fit and installation planning for commercial, industrial, and residential electrical projects.

Part Number
Cond. Size (AWG/Kcmil)Cond. NumberStrand CountDiameter Over Conductor (in)Insul. Thickness (mil)Jacket Thickness (mil)Approx. OD (in)Copper Weight (lb/1000ft)Approx. Weight (lb/1000ft)
THHN08B19-X81190.1433160.2175063
THHN06B19-X61190.1793160.2538195
THHN04B19-X41190.2264170.322128153
THHN03B19-X31190.2544170.35162189
THHN02B19-X21190.2864170.382204235
THHN01B19-X11190.3225280.439258301
THHN1/0B19-X1/01190.3615280.48326374
THHN2/0B19-X2/01190.4055280.524410464
THHN3/0B19-X3/01190.4565280.574518578
THHN4/0B19-X4/01190.5125280.627653719
THHN250B37-X2501370.5586290.684771844
THHN300B37-X3001370.616290.7539261016
THHN350B37-X3501370.6616290.80310801180
THHN400B37-X4001370.7056290.84812351341
THHN500B37-X5001370.7896290.93115431662
THHN600B61-X6001610.86570101.0318521992
THHN750B61-X7501610.96870101.13223152470
THHN1000B61-X10001611.11770101.28130873264

*All dimensions are nominal and subject to normal manufacturing tolerances

*TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Electrical & Engineering Data

This table outlines key electrical performance characteristics of THHN/THWN-2 cables. It includes values for bending radius, maximum pull tension, DC and AC resistance, inductive reactance, and allowable ampacity ratings at 75°C and 90°C. These specs are essential for engineers calculating electrical load capacity and installation conditions.

Part Number
Cond. Size (AWG/Kcmil)Cond. NumberMin Bending Radius (in)Max Pull Tension (lb)DC Resistance at 25°C (Ω/1000ft)AC Resistance at 75°C (Ω/1000ft)Inductive Reactance at 60Hz (Ω/1000ft)Allowable Ampacity at 75°C (Amp)Allowable Ampacity at 90°C (Amp)
THHN08B19-X810.91320.6530.7860.0525055
THHN06B19-X6112090.4110.4950.0516575
THHN04B19-X411.33330.2580.310.0488595
THHN03B19-X311.44200.2050.2460.047100115
THHN02B19-X211.55300.1620.1950.045115130
THHN01B19-X111.86690.1280.1540.046130145
THHN1/0B19-X1/011.98440.1020.1220.044150170
THHN2/0B19-X2/012.110640.0810.0970.043175195
THHN3/0B19-X3/012.313420.0640.0780.042200225
THHN4/0B19-X4/012.516920.0510.0620.041230260
THHN250B37-X25012.720000.0430.0530.041255290
THHN300B37-X3001324000.0360.0450.041285320
THHN350B37-X35013.228000.0310.0390.04310350
THHN400B37-X40013.432000.0270.0350.04335380
THHN500B37-X50013.740000.0220.0290.039380430
THHN600B61-X60015.248000.0180.0250.039420475
THHN750B61-X75015.760000.0140.0220.038475535
THHN1000B61-X100016.480000.0110.0180.037545615

* Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.

* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center

Stock Code by Color and Size

This table displays stock codes for Cablcon’s THHN/THWN-2 cables based on wire size and insulation color. Use this reference to identify the correct part number for your required strand size and color combination, streamlining ordering and inventory management.

Size (Strand)0-Black1-Red3-Blue9-White6-Brown5-Orange4-Yellow8-Gray2-Green7-Purple
8 (19)204883204909204917204891238477238493238485238501204925256586
6 (19)204933204958204966204941260695260679260687254649204974485607
4 (19)204990204982205633205005411702411710411694611778251728552486
3 (19)243469243485372763243477551078551079551080551081601971552533
2 (19)205021205013315812205039610169610171420653610172295832552534
1 (19)205047344598481945344580550890550888550887550891400192552488
1/0 (19)205054558773558774558771558778558779558777558781556315551539
2/0 (19)205062556113556114556111556119556117556116558784556115552535
3/0 (19)205070556121556122556120556127556125556124556698556123551541
4/0 (19)205088556129556130556128556135556133556132556697556131551540
250 (37)205096556137556138556136556143556141556140556552556139551025
300 (37)205104556145556146556144556150556149556148556551556147551026
350 (37)205112556152556153556151556157556156556155556707556154551027
400 (37)205120556160556161556158556165556164556163556550556162551029
500 (37)205138556168556169556166556173556172556171556549556170551599
600 (61)321471556176556177556174556181556180556179558859556178552485
750 (61)320994564946564944564945550909550908550907550910551700552536
1000 (61)289710


552644
552645
552647
564234

Versatile Copper Cable for Industrial and Commercial Use

Cablcon’s THHN, THWN-2, MTW, and DLO cables are built with copper conductors and tough PVC insulation, making them ideal for demanding environments up to 600V. Certified to UL and CSA standards and supported by value-added services like custom cutting and labeling.

54080